Unibrain 780 User Manual

Page of 72
Unibrain Fire-i 580/780/785/980 Operation Manual 
 
Page 49 
 
 
 
 
4.8.3.  SIO (RS232) special Commands 
SIO (RS232) special commands are non IIDC compliant and are specific mode for the Fire- cameras.   
0xF2F10018 
Auto-Sync Mode control register 
Bit 31 : auto sync enable 
Bit 30 : SIO enable mode (0 : custom mode, 1 : IIDC v1.32) 
Bit 27 : auto sync complete (read only. 1: ready, 0: not yet auto-sync)   
Read/Write 
            
Before using these commands serial communication parameters must be set at Serial_Mode_Reg (F2F22000h) 
Baud Rate 
Stop Bit 
Parity 
Flow Control 
57600 bps(default) 
1 bit 
None 
Non 
 
 
Command format :  [STX] [Command] [Data] [ETX] 
[STX]   
:  Command start character : ‘S’ 
Command]   :  Command length is 2byte. See next page command table. 
[Data]   
:  Data length is varied with each command. Data format is hexadecimal: ‘0’~’9’, ‘A’~’F’. 
[ETX]   
:   Command end character : ‘Z’   
 
Return value 
G’   
:  Command complete acknowledge. 
Gdd..d”   :  “dd..d”  is return data and hexadecimal character.   
U’   
:   Undefined command.   
 
Valid Character : ‘0’~’9’, ‘A’~’F’, ‘S’,’Z’  Invalid character is received is discarded.   
 
example)  Gain setting command with 0x200 value. 
All of “SA0200Z”,  “S A0 200 Z”,  “SA0 200Z”,  “S A0200 Z”, and “SKA0V200Z”  are parsed to 
SA0200Z”.