Symmetricom XLi IEEE 1588 User Manual
XLi IEEE 1588 Clock
99
997-01510-03, Rev. C, 12/12/2006
2
5
1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
where:
For example, enter the following string:
F108<CR>
The XLi responds (example):
F108 OSCILLATOR CONFIG TCVCXO<CR><LF>
F110 – J1 Input (TIET)
Note:
The Time Interval - Event Time (TIET) option is included as a standard feature on the XLi IEEE
1588 clock.
Note:
Using time code as a reference source is not supported for the XLi IEEE 1588 Clock.
F110 can configure the J1 input port on the Main CPU card as a time code reference source for the
system clock, or it can configure J1 as the input for TIET operation.
system clock, or it can configure J1 as the input for TIET operation.
Keypad
•
J1 Configuration: (IRIG-A, IRIG-B, NASA 36, TIET) Set to match the type of time code input.
•
J1 Time Reference (Available when J1 Configuration is IRIG-A, IRIG-B, NASA 36, not for TIET):
(Primary, Secondary, Standby) Identify the time code input as a primary or secondary reference
source. The function,
source. The function,
, uses this designation to for
reference source switching. Standby disables and removes J1 Input as a valid reference source.
Selecting Primary or Secondary automatically bumps another reference source with the same
setting (e.g.
Selecting Primary or Secondary automatically bumps another reference source with the same
setting (e.g.
) to Standby.
Note:
Configuring F110 for TIET forces J1 Time Reference to Standby. When reconfiguring the J1 as a
time code reference source input, be sure to set J1 Time Reference to Secondary or Primary.
•
Configure Code: (AM, DC) Set to the time code input signal type: AM for amplitude modulated,
or DC level shift. See the time code definitions in
for more
information.
•
Input Impedance: (For DC: 100 k
Ω or 50Ω. For AM: 100 kΩ only.) For DC code, set the
appropriate impedance level for the length of the input cable. Short runs (<200 ft.) get 100 k
Ω,
and long runs (>200) get 50
Ω.
F
= ASCII character F
108
= Function
number
<S>
= ASCII space character one or more
<CR>
= Carriage Return, equivalent to pressing the Enter key on a keyboard
<OSC>
= Oscillator type: TCVCXO, OCXO, HIGH (High Stability OCXO), or RUBIDIUM