Setting the J2 Output Configuration
To set the J2 Output Configuration, send a character string with the previously defined F111 entry format 
to the Serial/Network port. Only valid values are accepted.  The J2 Output Configuration can be set to 
specify one of several predetermined rates.  The following sections provide examples (and some 
explanations) for each.
Predetermined RATE output
For example, to produce a fixed 100 kPPS rate output, enter: 
F111 RATE 100KPPS<CR>
The XLi responds:
OK<CR><LF>
F113 – J3 Input Configuration (Aux Ref)
Note:  Freq Meas is currently unavailable as an option  for the standard XLi IEEE 1588 clock. Most of the
Freq Meas related information has been removed from this section.
Use function F113 to configure the J3 Input for one of the following settings:
Auxiliary Reference (Aux Ref) input
Disable all J3 inputs
F113 offers the following keypad settings:
J3 Input Configuration: Aux Ref, Freq Meas, Disabled
J3 Input Frequency: 1 MHz, 5 MHz, 10 MHz
J3 Input Impedance: 1k
Ω, 50 Ω
The factory settings are Disabled, 10 MHz, and 1k
Ω.
For J3 Input specifications, see 
.
Auxiliary Reference (Aux Ref) Input:
If an external frequency reference with better long-term stability than the XLi's own oscillator—such as a 
Cesium reference—is available, connect it to the J3 connector and enable Aux Ref using F113. Once 
this is done, the XLi will use the Aux Ref input (rather than its own oscillator) as its frequency source if 
the XLi's reference source(s) become unavailable. 
For example, with a single GPS receiver card configured as PRIMARY in F119, and F74 – Clock Source 
Control set to PRI,