Symmetricom XLi IEEE 1588 User Manual

Page of 216
 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1
Standard 110 VAC Power Supply
The XLi’s internal fault detector can monitor the three output voltages from the primary and the 
secondary power supplies. With the Primary Power or Secondary Power indicators in F73 enabled, a 
10% decrease in any of the output voltages triggers an alarm. See 
.
Warning: Ensure that a disconnect device, such as a switch, with the appropriate voltage/current rating, 
is provided when operating/installing the XLi.
Warning: Prior to servicing the interior of a unit with dual power supplies, remove both power cords.
Input connector:
IEC 320 type
Input voltage range:
Universal, 90 – 260 VAC and 110 – 370 VDC
Input frequency range:
47 Hz – 440 Hz
Isolation, ground:
For 110-370 VDC operation, the input is fully floating. Either 
input polarity may be strapped to chassis ground.
Isolation:
1,500 VAC, input to ground
Output Specifications:
+5.2 V (5.0 to 5.4 V), 25 watts, 0 to 5 amps
+12 V (11.4 to 12.6 V), 45 watts, 0 to 3.8 amps
-12 V (–11.4 to –12.6 V) 32 watts, 0 to 2.7 amps
Fan:
Exhaust 3-6CFM