Symmetricom XLi IEEE 1588 User Manual

Page of 216
68 
 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
1
where:
For example, enter:
F71<CR>
XLi responds:
F71 PHASE=-5.678E-09 s OFFSET=-1.986E-07 DRIFT= 6.013E-08/DAY DAC=24567<CR><LF>
F72 – Fault Status
Use function F72 to display the fault status of the clock.
Clock PLL – Locked or unlocked
Clock Status – Unlocked or locked plus one of the following reference types:
-
GPS Primary receiver
-
GPS Secondary receiver
-
PTP Primary (when configured as a PTP slave)
-
PTP Secondary (when configured as a PTP slave)
-
(IRIG-A, IRIG-B, NASA 36 not supported)
Primary power supply – OK or failed
Secondary power supply – OK or failed
Rubidium oscillator (if installed) – OK or fault
Command Line
To display the status of the fault detectors, enter:
F
=  ASCII string indicating function F71
<S>
=  ASCII space character one or more.
<MULT>
=  multiplier, 4 digits with decimal point.
E
=  ASCII character E for exponent.
s
=  ASCII character s for seconds abbreviation
<SIGN>
=  - for negative or <S> for positive.
<EXP>
=  2 digit exponent.
/DAY
=  ASCII characters, units of Drift Rate
<INT>
= integer, 
digits
<CR>
= carriage 
return.
<LF>
= line 
feed.