Command Line
To display the current settings, enter:
F74<CR>
XLi responds, using the following format:
F74<S><CLK SOURCE><CR><LF>
where:
For example, enter:
F74<CR>
XLi responds (example):
F74 PRI<CR><LF>
To select PRI-SEC-SEC as the new clock source/fail-over pattern, enter:
F74 PRI-SEC-SEC<CR>
XLi responds:
OK<CR><LF >
F90 – Code Output Configuration
Use function F90 to configure the time code output format (IRIG-A, IRIG-B, or NASA 36) and modulation 
type (AM or DC) on the XLi’s standard CODE output.
F
=  ASCII character F.
74
= function 
number.
<S>
= Space
<CLK SOURCE>
= Clock 
Source: 
PRI
SEC
PRI-SEC-SEC
PRI-SEC-PRI
PRI-NSEC-PRI
<CR>
=  carriage return character.
<LF>
=  line feed character.