Symmetricom 1000 User Manual

Page of 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 133
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
This command has a default access level of USER.
Normal Response Format
<cr><lf><lf>
^^^sid^date^time<cr><lf>
M^<ctag>^COMPLD
^^^”<aid>,aidtype:ntfcncde,condtype,srveff,ocrdat,ocrtim 
<:condscr>”<cr><lf>*
;
where * indicates zero or more of the preceding element
Sample Command
RTRV-ALM:::TS1000;
This command causes the TimeProvider to return all current alarms.
<aid>
Description
ALL (or null)
SYS
IMC
IOCm (m = 1 | 2)
PRS
INPp (p = 1 | 2)
OUTg (g = A | B | C | D)
Access identifiers
Value
Description
<aid>
Access identifier
aidtype
Access identifier type
EQPT – alarm associated with operation of the system
T1 – alarm associated with inputs or outputs
ntfcncde
Notification code:
MN – Minor alarm
MJ – Major alarm
CR – Critical alarm
condtype
Condition type – keyword associated with the command
srveff
Service affecting indicator
ocrdat
Occurrence date of the alarm
ocrtim
Occurrence time of the alarm
condscr
Optional condition description – text string enclosed in quotation 
marks