Symmetricom 1000 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
System Commands
140  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Normal Response Format
<cr><lf><lf>
^^^sid^date^time<cr><lf>
M ^ctag^COMPLD<cr><lf>
^^^”<aid>:<keyword>,<value>”<cr><lf>
;
Restarting the TimeProvider
Use the INIT-SYS command to reset the specified module or to clear all information 
stored in non-volatile memory. All users logged in to the TimeProvider are logged 
out and the user list is cleared. 
INIT-SYS:[<tid>]:<aid>:[<ctag>]::<keyword>;
This command has a default access level of ADMIN.
Sample Command
INIT-SYS::IOC1:::RESET;
Autonomous Message
TP-SSU 03-10-24 11:31:52
A 1193 REPT EVT
“IOC,EQPT:MN,RESET,NSA,03-10-24 11-30-42:\”MODULE HAS 
BEEN RESET\””
;
Caution: This command causes the local oscillator in the 
specified IOC to enter the Warm-up mode; the outputs remain in 
the holdover mode until the local oscillator locks on to the input 
reference signal.
All SYS parameters are reset, including the entire user list. You 
must create a new security-level user after issuing this command 
with the SYS:FACTORY aid and keyword.
<aid>
<keyword>
Description
SYS
FACTORY
Resets the SID, security, communication ports, and 
alarm settings to factory defaults (see 
)
IMC
IOCm 
m = 1 | 2
RESET
Performs a soft reset on the card and clears all alarms. 
Does not affect the SID, security, communication 
ports, and alarm settings