Symmetricom 1000 User Manual

Page of 224
097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 167
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Using Events to Troubleshoot
You can provision most events to generate an alarm; alarm levels include Critical 
(CR), Major (MJ), Minor (MN), Event, (NA), and Not Reported (NR). 
the event ID and the description of events for the IMC, IOC, and IOC Input.
Table 6-5.  Event Codes 
Event ID
Keyword 
Description
AID 
TYPE
Default Value/ 
Keyword
Description of Values
IMC Event Codes
ACCLVL
The user’s system 
access level has 
changed in the 
database
EQPT
SECURITY 
(when no users 
have been 
assigned to the 
system)
NONE – User has access to 
all commands; no Security 
has been assigned
USER – User can access 
User-level commands
ADMIN – User can access 
Admin-level commands
SECURITY – User can 
access all commands
ACO
Audio alarm has been 
deactivated
EQPT
N/A
N/A
ALMCHG
The IMC alarm 
parameters have 
changed
EQPT
N/A
Alarm keywords and values 
are listed in 
the user changes a value, the 
ALMCHG event is generated 
and contains the keyword and 
value
AOMERGE
Enable/Disable 
autonomous event 
generation for the 
current session
EQPT
ENABLE
ENABLE – Autonomous 
messages are displayed in 
the current session
DISABLE – Autonomous 
messages are not displayed in 
the current session
BAUD
The IMC serial port 
baud rate has 
changed
EQPT
9600
2400 | 9600 | 19200 | 28800 | 
38400 | 57600 
CMDCHG
The command access 
level has changed
EQPT
ACCLVL-USER
NONE | USER | ADMIN | 
SECURITY