Symmetricom 1000 User Manual

Page of 224
Chapter 3 Installing the TimeProvider
Making Connections
66
 TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Making Output Connections
You make the output signal connections using one of the Output modules listed in 
. Attach the module to the shelf before you connect cables.
Installing the Output Module
Attach the Output module to the shelf and secure it using the screws at the top and 
bottom of the module.
 lists the pinout for the DB9 four-connector Output module (090-58091-03), 
and the DB9 eight-connector Output module (090-58091-07) which are shown in 
.
Table 3-4.  Output Connector Modules 
Item Number
Description
Reference
090-58091-01
BNC Output module
090-58091-02
Wire-wrap Output module
090-58091-03
DB9 Output module – four connectors
090-58091-07
DB9 Output module – eight connectors
090-58091-04
SMZ/BT43 Output module
090-58091-05
Metric (Siemens) 1.0/2.3 Output module
090-58091-06
Metric (Siemens) 1.6/5.6 Output module
090-58071-02
Wire-wrap TIA/EIA-B-422 Output module
Table 3-5.  Pinout for the DB9 Output Module
4-Connector Output Module
8-Connector Output Module
Pin
Description
Pin
Description
1
Port A Tip
1
Chassis Ground
2
Port A Ring
2
Tip (or Ring)
4, 5, and 6
Chassis Ground
6
Ring (or Tip)
8
Port B Tip
3, 4, 5
Not used
9
Port B Ring
7, 8, 9
Not used