Eaton Pulsar Evolution 800 Tower 66226/KIT Leaflet
Product codes
66226/KIT
Technical characteristics
UPS -
Pulsar Evolution
Headquarters
140, avenue Jean-Kuntzmann
ZIRST - Montbonnot Saint-Martin
38334 Saint-Ismier Cedex - France
Tel.: +33 (0)4 76 18 30 00
140, avenue Jean-Kuntzmann
ZIRST - Montbonnot Saint-Martin
38334 Saint-Ismier Cedex - France
Tel.: +33 (0)4 76 18 30 00
PEVOL408UK
Associated communication
Solution-Pac software suite on CD
To control the protected servers
(clean shutdown) and for local
or remote supervision of the UPS.
To control the protected servers
(clean shutdown) and for local
or remote supervision of the UPS.
Management-Pac 2 software suite
on CD
NMS integration kit: HP Openview, IBM
Tivoli Netview, CA Unicenter, etc.
on CD
NMS integration kit: HP Openview, IBM
Tivoli Netview, CA Unicenter, etc.
SNMP/Web network card
To connect the UPS to the Ethernet
10/100 network, to relay SNMP
warnings and to supervise the UPS
via a single Web interface.
To connect the UPS to the Ethernet
10/100 network, to relay SNMP
warnings and to supervise the UPS
via a single Web interface.
Environment Sensor for the
SNMP/Web card
SNMP and Web monitoring
of Temperature & Humidity & the status
of 2 contacts.
SNMP/Web card
SNMP and Web monitoring
of Temperature & Humidity & the status
of 2 contacts.
Status information card
To relay the status of the UPS
in the form of free potential contacts
plus emergency stop.
To relay the status of the UPS
in the form of free potential contacts
plus emergency stop.
MGE PowerServices™
2-year warranty, including batteries.
Standard exchange of the product,
including the batteries, if they prove
to be defective.
Standard exchange of the product,
including the batteries, if they prove
to be defective.
Associated service
(1)
◗
Warranty+: peace of mind for your UPS,
extended 3-year warranty with standard
on-site exchange with the minimum
of delay.
extended 3-year warranty with standard
on-site exchange with the minimum
of delay.
1: Depending on the country, visit
www.mgeups.com/services.
Commercial models
Due to developments in technical standards and the equipment described in this document, we cannot be held liable for complianc
e with the characteristics indicated by the images and text unless they are confirmed by us. All the brand names referred to in
this document are protected by copyright.
Publication: MGE UPS SYSTEMS (July 2004) - Design and rewriting: 3c-evolution.com - Integration: Pamplemousse: +33 4 79 37 87 6
6 – Translation: TTP: +33 4 78 66 47 99.
Pulsar Evolution
500 800
1100
1500
2200 3000/3000XL
Power output, VA/W
500/350
800/560
1100/700 1500/1000 2200/1540
3000/2000
Technology
Line-Interactive High Frequency
Utilisation
Number of IEC 320 sockets
Number of IEC 320 sockets
4
4
4
4
8
8
Including Powershare sockets
2
2
2
2
2 x 2
2 x 2
Long battery discharge times
-
-
-
-
From 1 to 3 EXB
(EXB enclosures)
(1 to 12 for 3000 XL)
Performances
Automatic voltage control
Automatic voltage control
Booster/Fader
Output voltage form
Sinusoidal
Input voltage range
160 V/294 V, adjustable to 150 V/294 V using the supplied UPS Driver software
Frequency
50/60 Hz, automatic selection
Battery output voltage
230 V (adjustable to 200/220/240 V using the UPS Driver software supplied)
Functionalities
Automatic battery test
Automatic battery test
Weekly (periodicity adjustable using the UPS Driver software supplied)
Batteries Replaceable
on-line
Startup
Startup without mains supply
Battery protection
Against the effects of total discharges
RJ45 Line Network protection
Against over-voltages
Network Supervision/Administration
Communication ports
Communication ports
1 USB port USB + 1 Serial port
Software supplied
Local and SNMP agents supervision software
for Windows Server 2003/XP/2000/NT/98, Linux, Netware, OpenServer,
Unixware, SUN Solaris, IBM AIX, HP UX, Compaq Tru64, etc.
Supervision
Via an Internet navigator or SNMP supervisor
Slot for optional card
1 slot for the SNMP/Web card or status information card
Remote information transfer
Optional UPS Control remote display
Technical standards
Safety
Safety
IEC/EN 60950, IEC/EN 50091-1-1, TÜV GS-Mark
Electromagnetic compatibility
EN 50091-2, EN 55022/B
IEC 62040-2, IEC 61000-3-2, IEC 61000-3-3
Design, manufacture, services
ISO 9001
Identification marking
CE, TÜV GS-Mark
Dimensions (H x L x D, in mm) / weights (kg)
Dimensions of the Tower
Dimensions of the Tower
-
237 x
237 x
-
-
150 x 415
150 x 483
Dimensions of the Rack
44 (1U) x
44 (1U) x
44 (1U) x
88 (2U) x
438 x 353
438 x 499
438 x 522
438 x 640
Weight of the Tower/Rack
- /9
10.5/15.5
11.5/16
15/19
33.9
36.5 (XL: 20.8)
Weight of the EXB
-
-
-
-
41.9
Battery charge level
Groups of 4 sockets
for connecting devices
+ 2 sets of 2 programmable
sockets
for connecting devices
+ 2 sets of 2 programmable
sockets
Utilised power
Full user interface:
- on mains supply/battery
- booster/fader mode
- status of the programmable sockets
- replace battery or UPS fault
- on mains supply/battery
- booster/fader mode
- status of the programmable sockets
- replace battery or UPS fault
Connector
for additional
battery modules
for additional
battery modules
Slot
for the optional
communication
card
for the optional
communication
card
Protection for
data lines
data lines
Automatic
recognition of
battery extensions
recognition of
battery extensions
RS232 communication
port
port
USB communication
port
port
Removable logo providing access
to the battery compartment
to the battery compartment
Pulsar Evolution
500
800
1100
1500
2200
3000/3000XL
Tower
-
66 226
66 228
66 230
-
-
Rack
-
66 227
66 229
66 231
-
-
Convertible Tower/Rack
66 225
-
-
-
66 232
66 233/66 234
EXB models
66 235
Pulsar Evolution 3000