StarTech.com CONYX ECS0016 User Manual

Page of 140
Instruction Manual
116
powerman - power on/off nodes 
Synopsis
powerman [-option] [targets]
pm [-option] [targets] 
Options
-1, --on   Power ON targets. 
-0, --off   Power OFF targets. 
-c, --cycle   Power cycle targets. 
-r, --reset  Assert hardware reset for targets (if implemented by RPC). 
-f, --flash  Turn beacon ON for targets (if implemented by RPC). 
-u, --unflash   Turn beacon OFF for targets (if implemented by RPC). 
-l, --list  List available targets. If possible, output will be compressed into a 
host range (see TARGET SPECIFICATION below). 
-q, --query   Query plug status of targets. If none specified, query all 
targets. Status is not cached; each time this option is used, powermand 
queries the appropriate RPC’s. Targets connected to RPC’s that could 
not be contacted (e.g. due to network failure) are reported as status 
“unknown”. If possible, output will be compressed into host ranges. 
-n, --node   Query node power status of targets (if implemented by RPC). 
If no targets specified, query all targets. In this context, a node in the OFF 
state could be ON at the plug but operating in standby power mode. 
-b, --beacon Query beacon status (if implemented by RPC). If no targets 
are specified, query all targets. 
-t, --temp  Query node temperature (if implemented by RPC). If no targets 
are specified, query all targets. Temperature information is not interpreted 
by powerman and is reported as received from the RPC on one line per 
target, prefixed by target name.