Sony MP595 User Manual

Page of 88
Configuring the MP Modem to Report GPS and I/O 
Data
Rev 1.5  Jul.08
 
59
Digital I/O setup
The Digital Input/Output window (
Tools > Options > MP > 
 
Input/Output > Digital I/O
) is used to configure devices on the two 
digital I/O and two digital input ports. Each tab corresponds to 
a pin:
To configure a digital sensor or gauge, select the tab that corre‐
sponds to the pin you are using and complete the fields as 
follows:
Label: Provide a description of the sensor or gauge, up to 
20 characters in length.
Type: Select 
Input
Output
, or 
Not used
. (
Output
 is not 
available on tabs 3 and 4.)
Logic low name: Describe the state of the device at logic 
level low, up to 20 characters in length. (For example, if a 
switch in the off position leads to a logic low, you could 
choose to label it 
Switched Off
.)
Logic high name: Describe the state of the device at logic 
level high, up to 20 characters in length (such as 
Switched 
On
).
Alarm logic level: Assign an action associated with the I/O 
port:
·
high: A notification is sent, and the event is logged, if the 
state changes from a logic low to a logic high.
·
low: A notification is sent, and the event is logged, if the 
state changes from a logic high to a logic low.
·
log only: No notification is sent, but any change in logic 
level is logged.
The name and location of the log file is specified in the 
Input/Output window (
Tools > Options > MP > Input/Output
). 
By default, the log file is located in the program folder or 
user folder and is called MpIoLog.txt
Current value: Shows the current value of the port.
Digital Tab
Connector Pin
I/O 1
Input or output on pin 3
I/O 2
Input or output on pin 11
Input 3
Input on pin 4
Input 4
Input on pin 12