Installation
Example: Attaching a 7-type or 9-type 
viewfinder
For details on the attaching procedure, refer to the 
instruction manual furnished with the viewfinder.
Before attaching the viewfinder to the adaptor, check to be 
sure that the VF connector on the panning base mounting 
plate faces in the direction 90 degrees clockwise from the 
rear panel of the adaptor as shown in the figure for step 1 
below.
1
Place the viewfinder so that the mounting wedge on 
the rear of the panning base of the viewfinder enters 
the V-shaped groove on the panning base mounting 
plate of the adaptor. Make sure that the projections on 
the bottom of the viewfinder are in the appropriate 
positions.
2
Push the viewfinder by the handle so that the panning 
base is held securely by the panning base mounting 
plate.
The connection with the viewfinder will be made by 
the VF connector of the adaptor.
Pull the handle to check that the viewfinder is fixed to 
the adaptor.
3
Turn the viewfinder counterclockwise. Then turn the 
panning lock lever counterclockwise to lock the 
viewfinder in place.
To adjust the viewfinder position
When using an HDC-series camera
You can use the viewfinder in any of three positions.
To change the viewfinder position, proceed as follows:
1
Loosen the knob 1 of the handle and push in on the 
tab 2 to release the handle.
2
Rotate the handle toward the front.
In case of the HDLA1500, push the handle into the 
catch on the adaptor.
Note
Projections
Mounting wedge
Panning base
Bottom of the 
viewfinder
VF connector
Panning base 
mounting plate
Panning lock 
lever
1
2