Sierra Monitor Corporation IZS30 SERIES User Manual

Page of 26

4-4. Connection circuit 
 
Ionizer




POWER connector




 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
[Note 1]     

 

indicates the coating color for lead wire of dedicated cable 
[Note 2]        Connect [4. Stop signal of static charge elimination] to GND when starting 
the ionizer operation. 
When the terminal is open, the operation will stop.   
[Note 3]        [6. signal for abnormal sensor] and [8. signal for static charge elimination 
completion] functions only when the surface electric potential sensor is 
used. 
 
  Input and output operation list   
 
Name 
Lead wire 
color 
Signal 
Operation 
4  Stop signal of 
charge elimination   
Gray 
Input 
Connect 4 terminal to GND during operation 
Discharge stops when terminal 4 is open. 
5  Signal for abnormal 
High voltage 
White 
Output 
Tr1 in ionizer is ON when abnormal signal is being 
sent.   
6  Signal for abnormal 
sensing 
Orange 
Output 
Tf2 in ionizer is ON is conducted when abnormal 
signal is being sent.   
Signal for static 
charge elimination 
completion 
Yellow 
Output 
Tr 3 in ionizer is ON when static charge elimination 
is completed. 
1.DC+24V

Brown

4.Stop signal of   
charge elimination(Gray)
 
 "!#$%&')(*+
2.GND

Blue

 
3.7 NC

Green and red

Ionizer
 
INPUT
 
5.Signal for abnormal   
high voltage

White

 
 "!#$,-&'.0//*+
6.Signal for abnormal 
sensing

Orange

 
 "!#$,-&'.0//*+
8.Signal for static   
elimination completion
 
Max. DC28V,100mA
 







OUTPUT
 
24V
 
6.8k
 
1"243
Power supply 
DC21.6 to 26.4V 




GND 
or
OUTPUT
 
INPUT
 
PLC
 
F.G 
In
te
rn
al
 c
ir
cu
it