6. Selection and setting of equipment 
 
6-1. Sensing DC mode 
1. selection of bar length 
Select the length applicable to work size base on [2. static charge elimination area of 7-1. 
static charge elimination characteristics (reference)
2. Installation of ionizer body   
Installation of ionizer body: Install within 200mm to 2000mm from the target’s static charge 
See data of [1. Installation distance and static charge elimination time of 7-1. static charge 
elimination characteristics (reference)] for static charge elimination time. 
3. Installation of surface electric potential sensor 
Direct  detecting  hole  to  the  charged  face,  and  install  it  within  50mm  from  the  target’s  static 
charge.    (should be installed near the target’s static charge as close as possible. 

 
4. Wiring   
Connect ionizer body and surface electric potential sensor with a dedicated cable. 
Connecting ionizer body and surface electric potential sensor automatically sets the mode 
to sensing DC mode.   
Power supply and each input/ output is wired with the dedicated cables.    See [wiring table for 
power supply cable IZS30-CP of 4-3 cable connection]  for wiring table.     
5. Pneumatic piping 
Since fitting with check valve is used, plug should not be connected on the other side even with   
single piping.   
Pipe  4 tube.    See [3. specifications] for air flow rate. 
When piping is long, required flow rate might not be obtained without both-side piping.   
 
6-2. Pulsed DC mode/ DC mode 
1. Selection of bar length 
Select the length applicable to work size base on [2. static charge elimination area of 7-1. 
static charge elimination characteristics (reference)
2. Installation of ionizer body   
Install within 50mm to 2000mm from the target’s static charge 
See data of [1. Installation distance and static charge elimination time of 7-1. static charge 
elimination characteristics (reference)] for static charge elimination time. 
3. Selection of ion generation frequency   
Set selection switch with a screw driver referring to P1
>
data on operating frequency and static   
charge elimination time
?
.   
A screw driver slot for selection switch configures like a small arrow. Direct the tip of the arrow 
to 
the applicable position and set it. 
Setting  the  switch  [8]  or  [9]  shift  the  mode  to  DC  mode,  which  discharges  plus  and  minus 
continuously. 
4. Wiring   
Connect ionizer body and surface electric potential sensor with a dedicated cable. 
Connecting ionizer body and surface electric potential sensor automatically switches the mode 
to sensing DC mode.   
Power supply and each input/ output is connected with the dedicated cables.    See [wiring table 
for power supply cable IZS30-CP of 4-3 cable connection]  for wiring table.     
5. Pneumatic piping 
Since fitting with check valve is used, plug should not be connected on the other side even with   
single piping.   
Pipe  4 tube.    See [3. specifications] for air flow rate. 
When piping is long, required flow rate might not be obtained without both-side piping.