Sierra Monitor Corporation IZS31 User Manual

Page of 26
 
16
4-2. Pulse DC mode 
 
1. Selection of the bar length 
・Select an appropriate length that is suitable for the work size, static charge elimination characteristics 
and static charge elimination range.   
 
2. Installation of the ionizer 
・Keep the distance between the ionizer and charged object within 50 to 2000mm. When the auto 
balance sensor is used, the distance should be ranged from 100 to 2000mm. When the ionizer is used 
outside of the operating conditions, it might not operate properly. In that case, be sure to check if the 
ionizer will operate properly.   
 
3. Installation of the sensor 
・Install the auto balance sensor to adjust the ion balance.     
・Horizontally place the auto balance sensor under the ionizer, and install the sensor on the same level 
with a workpiece as much as possible. 
・When he auto balance sensor is connected, the balance adjustment trimmer will be invalid.   
 
4. Setting of the maintenance level selecting switch   
・[manual operation] or [auto operation] can be selected when the ion balance needs to be adjusted with 
the auto balance sensor.   
 
 Description 
 
Switch 
setting 
Manual 
operation 
Ion balance is adjusted when the maintenance 
start-up signal is input or when the power   
supply of the Ionizer is applied.   
The ion-balance adjustment values are 
retained per ion-production frequency. When 
the ion-production frequency is changed, adjust 
the ion balance.   
Once the ion-balance adjustment is completed, 
the ion balance adjustment will not be executed 
unless the next maintenance start-up signal is 
input. Therefore, the auto balance sensor can 
be removed.   
MANUAL 
 
Auto operation
Ion-balance is continuously adjusted.   
Once the auto balance sensor is removed, 
manually adjust the ion-balance with a balance 
adjustment trimmer.   
AUTO 
 
* Set the switch in line with the detection level of the dirt on the electrode needle.   
 
・When the auto balance sensor is not used, change the switch setting to AUTO, and manually adjust the 
ion-balance with a balance adjustment trimmer.   
 
 
 
 
・Set the level for detecting the dirt on the electrode needle.   
・Select the level from H(High), M(Middle) or L(Low). The dirt on the electrode needle cannot be 
detected with other levels.   
 
 
 
 
 
 
・The dirt detection will begin once the maintenance start-up signal is input.   
・If H, M and L levels are set, ion balance adjustment is executed after the dirt on the electrode needle is 
detected. 
 
MANUAL
AUTO
Model  NuFile 
00
 
   
 
Balance aadjustment trimmer
 
 
H(High)  ・・・  The level that doesn’t affect the static charge eliminating time (Even a small amount of   
dirt can be detected).   
M(Middle)  ・・The level that can notify the maintenance just before the static charge elimination time becomes   
slow.  
L(Low)  ・・・  The level that the static charge elimination time becomes slower than the one in the initial state.