Sierra Monitor Corporation IZS31 User Manual

Page of 26
 
21
 
6.  LED display 
„ POWER  LED  ・・・  The power supply input and the connection of the sensors are displayed.   
 
 
 
 
 
 
LED name 
Functions 
MAIN 
Lights up when the power supply is applied. (Green) 
(Flashes when wrong power supply is applied.  ) 
POWER 
SNSR Goes 
out. 
 
„ ION  LED  ・・・  The discharged ion polarity is displayed. 
 
 
 
 
 
LED name 
Functions 
+ 
Lights on when plus ions are generated.(Orange) 
OK Goes 
out. 
ION 
- 
Lights on when minus ions are generated.(Blue) 
 
 
„ ALARM  LED  ・・・  Failure of the ionizer is displayed.   
 
 
 
 
 
LED name 
Functions 
HV 
Lights up when overcurrent is applied to the electrode needle.  (Red) 
SNSR Goes 
out. 
ALARM 
NDL 
CHECK 
Goes out. 
7.  Alarm 
Type of alarm 
Description 
How to reset 
Abnormal high voltage 
Notifies when overcurrent such as high voltage 
leakage occurs. The ion-discharge-output is 
stopped, HV ALRM sets off and output the 
signal for failure. 
Turn off the power supply to solve the problem. 
Once it’s solved, apply the power supply again. 
Or turn on and off the discharge-stop signal. 
CPU failure 
Notifies that CPU fails due to noise. All LEDs   
Flashes, and the signal for CPU failure is   
output.  
Turn off the power supply to solve the problem. 
Once it’s solved, apply the power supply again. 
Or turn on and off the discharge-stop signal. 
 
8.  Timing chart 
„  Timing chart with a normal operation 
 
 
 
 
 
 
ON
 
Input
OFF
 
ON
 
(Operation)
Input
OFF
 
ON
 
(Discharge)
OFF
 
Power supply DC24V
Discharge-stop signal
 
State of ion discharge