Siemens Wireless Office Headset SIMATICS PCS7 User Manual
SIMATIC PCS 7 TeleControl system components
11
PCS 7 TeleControl blocks for system-conformant operator
control and monitoring
control and monitoring
The RTUs are integrated into the PCS 7 TeleControl Operator
System by means of the PCS 7 TeleControl blocks such that
there is no difference for the operator with regard to operat-
ing philosophy and alarm behavior for the central or remote
automation functions.
System by means of the PCS 7 TeleControl blocks such that
there is no difference for the operator with regard to operat-
ing philosophy and alarm behavior for the central or remote
automation functions.
The blocks required for data conditioning and display are
saved in a library. These blocks support SIMATIC PCS 7 compli-
ant operator control by means of symbols and faceplates, as
well as the hierarchy of SIMATIC PCS 7 fault messages.
saved in a library. These blocks support SIMATIC PCS 7 compli-
ant operator control by means of symbols and faceplates, as
well as the hierarchy of SIMATIC PCS 7 fault messages.
In addition to blocks for processing of process data, the
library also contains blocks for diagnostics and for control
of communication. If necessary, the supplied basic library can
be extended by new script-based block types specific to the
project by using the DBA Type Editor.
library also contains blocks for diagnostics and for control
of communication. If necessary, the supplied basic library can
be extended by new script-based block types specific to the
project by using the DBA Type Editor.
Long-term archiving and
logging
logging
The PCS 7 TeleControl Operator System includes a high-perfor-
mance cyclic archive based on Microsoft SQL Server for time-
limited saving of process values and messages/events. Data
from this cyclic archive can be exported time-controlled or
event-controlled to a long-term archive (StoragePlus/central
archive server).
mance cyclic archive based on Microsoft SQL Server for time-
limited saving of process values and messages/events. Data
from this cyclic archive can be exported time-controlled or
event-controlled to a long-term archive (StoragePlus/central
archive server).
The logging system of the PCS 7 TeleControl Operator System
supports the display and evaluation of data recorded during
operation by means of various predefined types of protocol
which can also be matched individually:
supports the display and evaluation of data recorded during
operation by means of various predefined types of protocol
which can also be matched individually:
• Message sequence report
• Message and archive log
• Measured value log
• Operator input log
• System message log
• User log
• Message and archive log
• Measured value log
• Operator input log
• System message log
• User log
The logs saved in EMF format can be previewed on the screen,
and can be printed manually or time- or event-controlled.
and can be printed manually or time- or event-controlled.
In order to comply with statutory directives and standards it
may be necessary to provide special proof, e.g. proof of con-
formity with the ATV M260 standard for sewage treatment
plants. The SIMATIC PCS 7 add-on product ACRON equipped
with additional functionalities for long-term archiving and
logging provides excellent support for this purpose.
may be necessary to provide special proof, e.g. proof of con-
formity with the ATV M260 standard for sewage treatment
plants. The SIMATIC PCS 7 add-on product ACRON equipped
with additional functionalities for long-term archiving and
logging provides excellent support for this purpose.