3.2 AT+CIND
s
TC63_ATC_V00.490
Page 69 of 501
5/24/05
Confidential / Draft - Do not copy
 
String values and their 
 ranges.
More indications are available via 
. Therefore use of 
 for control of all indications is recom-
mended.
The following indications are accessible via 
“battchg“
Battery charge level 0..4 or 5 if no measuring is performed, e.g because no bat-
tery is connected. Also refer to 
“signal“
Signal quality (0..7) 
The indicated value is the bit error rate of the signal received. Bit errors are esti-
mated values. See also 
“service“
Service availability (0-1)
0: Not registered to any network
1: Registered to home network or, if "roam"=1 then registered to another net-
work 
“sounder“
Sounder activity (0-1)
Reports every event that causes the ME to generate a tone.
Value 1 means for example:
Incoming call - ME is ringing. Note that the URC "
: sounder" will be out-
put only if ringing tones are activated with 
Waiting call - ME generates waiting call tone (if call waiting is enabled).
Outgoing call - ME generates Call Progress tone.
Outgoing call - ME generates BUSY tone.
The value changes to 0 when the tone stops. 
“message“
Unread short message at memory location 
 (0-1); refer to 
 
“call“
Call in progress (0-1). Indicator value is "1" if at least one call is in state "active"
or "held".
Depending on the parameter 
 selected with 
 the indicator
"call" will be issued 
• when a state transition ends in state "active" or state "unknown", if
="restricted", 
• when any state transition (including transitions beginning or ending in state
"unknown") occurs in the list of active calls or when a traffic channel is
established, if 
="verbose". 
Also refer to Section 
“roam“
Roaming indicator (0-1)
0: Registered to home network or not registered
1: Registered to other network 
“smsfull“
A short message memory storage in the MT has become full (1) or memory
locations are available (0), i.e. range is (0-1) 
“rssi“
Received signal (field) strength (0..5) 
0: signal strength <= -112 dbm
1-4: signal strength in 15 dbm steps
5: signal strength >= -51 dbm
Received signal (field) strength can also be obtained with 
. However,
the signal strength is scaled to value range 0..31 by this command. 
0
Indicator is deregistered. The indicator will not be presented as "
" URC,
but can be queried with 
?. 
[1]
(&F)(P)
Indicator is registered, indicator event report allowed. 
<indDescr>
(str)
<mode>
(num)