Russound CA4 Controller Kit CA4 User Manual

Page of 32
11
Russound CA4 System Installation  Manual
SYSTEm CONFIGURATION 
/
/
/
/
Keypad Configuration
Controller / Keypad Configuration
The CA4 Wall Port jacks are located on the rear of the controller. These RJ-45 
ports  must  be  connected  to  the  corresponding  jacks  on  the  wall  port.  Each 
keypad is then connected to the wall port.  
All  CAT-5  connections  are  made  with  RJ-45  connectors  using  the  T568A 
Wiring Standard configuration. For a clean installation use the included RJ-45 
CAT-5  pass-through  cables  to  connect  from  the  controller  wall  port  jack  to 
the corresponding one on the CA4-WP. Using the same wiring configuration 
to terminate the ends, route a CAT-5 cable from the wall port to each of the 
keypads. Cables from the controller to the wall port should not exceed 6 feet 
(2m). 
The maximum recommended CAT-5 cable length is 240 feet (73.2m) between 
the wall port and the keypad.  
Note: All four CAT-5 cables must be connected between the controller and 
wall port for proper operation. 
Caution:  Cables  between  the  wall  port  and  the  controller  must  match 
numerically  (#1  on  Controller  to  #1  on  Wall  Port,  etc.).  Swapping  cables  to 
different ports can damage the equipment.