Rockwell SoniCrafter BT8960 User Manual

Page of 104
72 
4.0   Electrical & Mechanical Specifications
 
4.2   Recommended Operating Conditions
Bt8960
Single-Chip 2B1Q Transceiver
 N8960DSB
4.2  Recommended Operating Conditions
Table 4-2.  Recommended Operating Conditions  
Symbol
Parameter
Minimum
Typical
Maximum
Units
V
DD1
Digital Core-Logic Supply Voltage
4.75
5.0
5.25
V
V
DD2
Digital I/O-Buffer Supply Voltage
4.75
5.0
5.25
V
V
AA
Analog Supply Voltage
4.75
5.0
5.25
V
V
IH
High-Level Input Voltage
2.0
V
DD2 
+ 0.3
V
V
IL
Low-Level Input Voltage
–0.3
+0.8
V
V
IHX
High-Level Input Voltage for XTALI / MCLK
0.8*V
DD2
V
DD2 
+ 0.3
V
V
ILX
Low-Level Input Voltage for XTALI / MCLK
–0.3
0.2*V
DD2
V
C
L
Output Capacitive Loading
(1)
60
pF
T
A
Ambient Operating Temperature
(2)
–40
+85
˚C
Notes: (1). Capacitive loading over which all digital output switching characteristics are guaranteed. 
(2). Still-air temperature range over which all electrical characteristics and timing requirements/characteristics are guaran-
teed.