Rockwell SoniCrafter BT8960 User Manual

Page of 104
76 
4.0   Electrical & Mechanical Specifications
 
4.5   Channel Unit Interface Timing
Bt8960
Single-Chip 2B1Q Transceiver
 N8960DSB
4.5  Channel Unit Interface Timing
Table 4-7.  Channel Unit Interface Timing Requirements, Parallel Master Mode 
Symbol
Parameter
Minimum
Maximum
Units
14
TQ[1,0] Setup prior to QCLK Falling Edge 
100
ns
15
TQ[1,0] Hold after QCLK Low
25
ns
Table 4-8.  Channel Unit Interface Switching Characteristics, Parallel Master Mode 
Symbol
Parameter
Minimum
Maximum
Units
16
RQ[1,0] Hold after QCLK Rising Edge 
–50
ns
17
RQ[1,0] Delay after QCLK High
50
ns
Figure 4-3.  Channel Unit Interface Timing, Parallel Master Mode
14
15
16
17
RQ[1,0]
QCLK
TQ[1,0]