OPERATION
LED FUNCTION OF RIDGID 24V LITHIUM-ION CHARGER
See Figure 4.
LED
INDICATOR
BATTERY 
PACK
RED
LED
GREEN
LED
ACTION
Charging
Fast charging
ON
OFF
Charges in 1 hour
Charging
Deeply 
Discharged
ON
OFF
Charger pre-charges battery until normal voltage 
is reached, then begins fast charge mode. May 
take longer than 1 hour to fully charge.
Full
Maintenance 
charging
OFF
ON
Fast charging is complete 
Charger maintains charge mode
Evaluate
Hot battery 
pack
Flashing OFF
When battery pack reaches cooled temperature, 
charger begins fast charge mode
Evaluate
Cold battery 
pack
Flashing OFF
When battery pack reaches warmed temperature, 
charger begins fast charge mode
Defective Defective
Flashing Flashing Battery pack or charger is defective
•  If defective, try to repeat the conditions a second time by removing and reinstalling the battery 
pack. If the LED status repeats a second time, try charging a different battery.
•  If a different battery charges normally, dispose of the defective pack (see Maintenance section).
•  If a different battery also indicates “Defective,” the charger may be defective.
Battery  packs  for  this  tool  are  shipped  in  a  low  charge 
condition  to  prevent  possible  problems.  Therefore,  you 
should  charge  the  pack  until  the  light  on  the  front  of  the 
charger changes from flashing green to continuous green.
NOTE: Batteries will not reach full charge the first time they 
are  charged.  Allow  several  cycles  (operation  followed  by 
recharging) for them to become fully charged. This is normal 
for nickel-cadmium batteries.
TO CHARGE
 
Charge the battery pack only with the charger provided.
 Make sure the power supply is normal household voltage, 
120 volts, 60 Hz, AC only.
  Connect the charger to a power supply.
  Attach the battery pack to the charger by aligning the 
raised ribs on the battery pack with the grooves in the 
charger,  then  slide  the  battery  pack  onto  the  charger. 
See Figure 5.
  The battery pack will become slightly warm to the touch 
while charging. This is normal and does not indicate a 
problem.
  Do not place the charger in an area of extreme heat or 
cold. It will work best at normal room temperature.
  For  average  charge  times,  refer  to  the  chart  on  the 
following page. 
THE FOLLOWING INSTRUCTIONS ARE FOR RIDGID NICKEL-CADMIUM BATTERY PACKS AND 
CHARGERS.
  When  the  batteries  become  fully  charged,  unplug  the  
charger from the power supply and remove the battery 
pack.
CHARGING A HOT BATTERY PACK
When using the tool continuously, the batteries in the battery 
pack  will  become  hot.  You  should  let  a  hot  battery  pack 
cool down for approximately 30 minutes before attempting 
to recharge. When the battery pack becomes discharged 
and is hot, the green LED will be off and the red LED will 
begin flashing. 
When the battery pack cools down to approximately 104°F 
(40°C),  the  charger  will  automatically  begin  fast  charge 
mode.
CHARGING A COOL BATTERY PACK
If the battery pack is below normal temperature range, the 
red LED will begin flashing and the green LED will be off. 
When the battery warms to a temperature of more than 41°F 
(5°C), the charger will automatically begin fast charge mode.
NOTE:  Refer  to  CHARGING  THE  BATTERY  PACK  for 
normal recharging of batteries. If the charger does not charge 
your battery pack under normal circumstances, return both 
the battery pack and charger to your nearest repair center 
for electrical check. For the location of your nearest repair 
center, please call 1-866-539-1710.