Renesas M32R-FPU User Manual

Page of 192
3
3-116
M32R-FPU Software Manual (Rev.1.01)
TRAP
TRAP
EIT-related instruction
Trap
[Mnemonic]
TRAP  #imm4
[Function]
Trap occurrence
BPC = PC + 4;
BSM = SM;
BIE = IE;
BC = C ;
IE = 0;
C = 0;
call_trap_handler( imm4 );
[Description]
TRAP generates a trap with the trap number specified by the 4-bit immediate value.
IE and C bits are cleared to "0".
[EIT occurrence]
Trap (TRAP)
[Encoding]
0001
0000
1111
imm4
TRAP  #imm4;
INSTRUCTIONS
3.2 Instruction description