Decoded (HHP)
Concatenation
“Codabar” supports symbol concatenation. When you enable Concatenation, the 
imager looks for a Codabar symbol with a “D” start character that is adjacent to a 
symbol with a “D” stop character. In this case, the two messages are concatenated 
into one with the “D” characters omitted.
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable 
characters), including check digit(s). Double-tapping on these parameters displays a 
screen in which you can set the minimum and maximum allowable code lengths – 2 
to 60.
Field Size/Char
Refer to page 148 for details.
6.25.2.13 MSI Plessey
Enabled
Set this parameter to on to enable MSI.
Enable Plessey
Set this parameter to on to enable Plessey.
Check Char
When this parameter is set to Validate only, the integrity of the symbol is checked to 
ensure that it complies with specified algorithms.
If “Check Char” is set to Validate and Transmit, the check character is validated and 
transmitted with the data.
Setting this parameter to None disables this function.
Minimum And Maximum Length
These parameters apply to MSI bar codes. The length of a code refers to the number 
of characters (i.e., human readable characters), including check digit(s). Double-
tapping on these parameters displays a screen in which you can set the minimum 
and maximum allowable code lengths – 4 to 48.