Psion Teklogix 8100107B User Manual

Page of 396
WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual 171
Chapter 6: Settings
Decoded (HHP)
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable 
characters), including check digit(s). Double-tapping on these parameters displays a 
screen in which you can set the minimum and maximum allowable code lengths – 1 
to 60.
Field Size/Char
Refer to page 148 for details.
6.25.2.20 RSS Code (Reduced Space Symbology)
Enable
Setting this parameter to on enables “RSS Code” scanning capability.
Enable RSS Limited
‘RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade 
item number) that begin with either a 0 or a 1. It is not stackable and is not designed 
to be read omni-directionally.
Enable RSS Expanded
“RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but 
they can be split into sections and stacked several rows high, reducing the length of 
the symbol, while increasing the capacity of data that can be stored. “RSS 
Expanded” code can be omni-directionally scanned
.
Minimum And Maximum Length
The length of a code refers to the number of characters (i.e., human readable 
characters), including check digit(s). Double-tapping on these parameters displays a 
screen in which you can set the minimum and maximum allowable code lengths – 1 
to 74.
Field Size/Char
Refer to page 148 for details.