Chapter 6: Settings
Code 93
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths 
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a 
selected length. Choosing Two discrete lengths allows you to decode only those 
codes containing two selected lengths. Length within a range allows you to decode 
a code type within a specified range from 5 to 55.
CLSI Editing
When enabled, this parameter strips the start and stop characters 
and inserts a space after the first, fifth, and tenth characters of a 14-character 
Codabar symbol. 
Note: Symbol length does not include start and stop characters.
NOTIS Editing
When enabled, this parameter strips the start and stop characters from decoded 
Codabar symbol.
Field Size/Char
Refer to page 117 for details.
6.20.1.11 Code 93
Enabled
Set this parameter to on to enable “Code 93” or off to disable it.
Set Length L1 And Set Length L2
Lengths for “Code 93” can be set for Any lengthLength within a rangeOne 
discrete length
 or Two discrete lengths. The length of a code refers to the number of 
characters (i.e., human readable characters), including check digit(s).
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths 
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a 
selected length. Choosing Two discrete lengths allows you to decode only those 
codes containing two selected lengths. Length within a range allows you to decode 
a code type within a specified range from 4 to 55.