Psion Teklogix Schnellstart- Anleitung 7525 User Manual

Page of 364
Chapter 8: Expansion Modules
Enabling The SE 923HP Scanner
270
Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual
The SE 923HP scanner (model # WA9002) is the internal scanner module available 
with the WORKABOUT PRO. To install it:
Remove the battery. If your unit is using AC power, disconnect it.
Remove the stylus and then, remove the end-cap at the top of the 
WORKABOUT PRO.
Slide the SW1401 switch to the left to shut off internal battery power.
Remove the back plate from the unit.
A scanner flex cable is already attached to the WORKABOUT PRO. You need to 
connect the flex cable to the internal scanner module.
Remove the adhesive tape that holds the flex cable in a folded position.
Insert the flex cable into the connector on the scanner module (refer to 
Figure 8.9 on page 268). If necessary, use pincers to hold the flex cable.
Fit the scanner module over the back of the WORKABOUT PRO—it 
replaces the back plate of the unit.
Fasten the module in place with the screws provided. Tighten the screws to 
a torque of 3 lbs-in (3kgf-cm), or until finger tight.
Slide the SW1401 power switch to the right to turn power back on, and 
replace the end-cap and battery. Tighten the end-cap screws to a torque of 3 
lbs-in (3kgf-cm), or until finger tight
8.1.7.1
Enabling The SE 923HP Scanner
Simultaneously, press and hold down the <BLUE> <ENTER> and left 
<SCAN> keys for a minimum of 6 seconds. A 
Command>
 prompt is dis-
played on the WORKABOUT PRO screen.
Type s to display the 
Scanner>
 prompt. A list of supported scanners is dis-
played.
Type 3 and press <ENTER> to activate scanner type SE 923HP.
At the 
Command>
 prompt, type 1 (one) to reboot the unit to Windows Mobile 
2003 SE.