Psion Teklogix Hand-Held Computer 7530 G2 User Manual

Page of 296
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
169
Chapter 5: Configuration
Decoded (Internal) Scanners
Convert To EAN 13
If this parameter is enabled, an I 2 of 5 bar code is converted to EAN 13.
Field Size/Chars
Refer to page 148 for details.
5.11.3.15 MSI Plessey
Enabled
Set this parameter to on to enable “MSI Plessey”.
Set Length L1 And Set Length L2
Lengths for “MSI Plessey” can be set for Any length, Length within a range, One 
discrete length 
or Two discrete lengths. The length of a code refers to the number of 
characters (i.e., human readable characters), including check digit(s). 
Double-tapping on this parameter displays a dialog box labelled Set Code Lengths 
where you can define the code length that will be recognized by your scanner.
Choosing One discrete length allows you to decode only those codes containing a 
selected length. Choosing Two discrete lengths allows you to decode only those 
codes containing two selected lengths. Length within a range allows you to decode 
a code type within a specified range from 6 to 55.
Check Digits
Double-tapping on this parameter displays a dialog box in which you can choose 
One or Two check digit(s). 
If this parameter is set to One, it is assumed that the last digit is a check digit. If 
“Check Digits” is set to Two, it is assumed that the last two digits are check digits.
Note: If 
Two
 check digits is selected, an MSI Plessey “Check Digit Algorithm” 
must also be selected. See page 9-88.
Transmit Check Digit
If this parameter is enabled, the check digit is included with the bar code data.