Technical Bulletin
SoundPoint 
®
 IP, SIP 2.1
3
Flash Parameter Configuration
The global device parameter has been modified to include the following: 
Trademark Information
Polycom®, SoundPoint®, and the Polycom logo design are registered trademarks of Polycom, Inc. in the U.S. and 
various countries. All other trademarks are the property of their respective companies.
Name
Possible Values
Description
device.syslog.serverName
dotted-decimal IP address
OR
domain name string
The syslog server IP address or host name.
The default value is NULL.
device.syslog.transport
None=0,
UDP=1,
TCP=2
The protocol that the phone will use to write to the 
syslog server. 
If set to “None”, transmission is turned off, but the 
server address is preserved.
device.syslog.facility
0 to 23
A description of what generated the log message. 
For more information, refer to section 4.1.1 of RFC 
3165.
The default value is 16, which maps to “local 0”.
device.syslog.renderLevel
1 to 6
Specifies the lowest class of event that will be 
rendered to syslog. It is based on 
log.render.level 
and can be a lower value.
Refer to Basic Logging <level/><change/> and 
<render/> on page 138
 
of the 
SIP 2.0 
Administrator’s Guide
.
device.syslog.prependMac
Enabled, Disabled
If enabled, the phone’s MAC address is prepended 
to the log message sent to the syslog server.
Note
The parameters for this feature should be put in separate configuration files to 
simplify maintenance. Do not add them to existing configuration files (such as 
sip.cfg). Create a new configuration file for parameters that should apply to all 
phones. 
Polycom recommends that you test the new configuration files on two phones 
before initializing all phones.