Page 53
Power Cable Specification
The voltage rating and the current rating of the power cord set shall be higher than the rated voltage
and current of this unit. The voltage rating of the power cord set shall be higher than the power source.
For the U.S. and Canada:
Power cord must be UL listed and CSA labeled. Type SJT, SVT, ST, SJO or SO, 3-conductors, No. 18
AWG, rated 125v, 10A
For Germany and continental Europe:
STROMANFNAHME: 100-240 VAC, 50/60 Hz, 6A.
Für eine 230V-Anwendung, ist eine harmonisierte <HAR> konfektionierte Leitungsschnur, Typ
H05vvf3G1.00, die für 250V/10A oder die Gleichwertigkeit geeognet ist, zu benutzen.
If there are any questions in regards to the proper cord sets, consult the distributor.
SCSI Cable Specification
SCSI Cables and Connectors
Plasmon recommends using Wide LVD SCSI cables and connectors that conform to SCSI-3
specifications.
NOTE
To comply with the regulations and standards in this manual, all
SCSI cables and connectors used with the library must be
properly shielded.
SCSI Cable Length
Plasmon recommends using SCSI cables that conform to SCSI-3 specifications with high density 68-
pin connectors. The following table shows the allowable cable lengths for the LVD SCSI interface.
Table 12. Maximum Allowable SCSI Cable Length (LVD) 
SCSI Termination
The Plasmon D875 - D2175 libraries are terminated internally. No external termination is required.
Library Internal Cable Length
Allowable External Cable 
Length
Bus 1
10 ft (3 M)
29 ft (9 M)
Bus 2
3 ft (1 M)
36 ft (12 M)
Bus 3
3 ft (1 M)
36 ft (12 M)