Plasmon V15 User Manual

Page of 138
Appendix C
Page 129
214
Invalid Slot Config. The Max-
imum Number of Slots is set to 
1 and the last slot is config-
ured as a cleaning slot.
Change the Max Addressable Slot to a value greater 
than 1 (see Setting the Max Addressable Slot Option in 
Chapter 3) or turn off the Clean Slot Option (see Setting 
the lean Slot Option
 in Chapter 3).
220
OS failure. The library’s oper-
ating system experienced an 
error.
Make sure the library and tape drives are not being used 
by any host, then reset the library from the operator 
panel. 
If the error persists, contact your service provider.
221
Could not set alarm. The 
library’s operating system 
experienced an error.
222
OS message failure. The 
library operating system expe-
rienced an error.
225
M Bus Timeout. No acknowl-
edgement from internal M bus 
device
Ensure no commands are active to the library. Reset the 
library. If error persists, contact your service provider.
226
Mbus interrupt timeout. The 
robot command processor 
timed out before setting an 
interrupt.
Make sure the library and tape drives are not being used 
by any host, then reset the library from the operator 
panel. 
If the error persists, the robot may need to be replaced. 
Contact your service provider.
227
Mbus acknowledge failure. 
The robot command processor 
failed to respond to a com-
mand.
230
DHCP server timeout. The 
Ethernet DHCP server could 
not assign an IP address for 
the library.
This error occurs only when the optional Ethernet inter-
face is installed. Set the network address to Static and 
set the desired IP address (see Setting Ethernet 
Addresses
 in Chapter 4).
236
SCSI Configuration Error. 
Configuration start ID is 
invalid.
If power cycling the library does not recapture this infor-
mation, contact your service provider.
237
SCSI Configuration Error. 
Configuration field is invalid.
238
SCSI Configuration Error. 
Configuration value is invalid.
239
SCSI Configuration Error. 
Configuration buffer ID is 
invalid.
LCD 
Code
Description
Corrective Action