Pitco Frialator PITCO PCF18 User Manual

Page of 10
NORMAL OPERATION 
 
Daily operating procedures 
1.  Prior to use, unit must be installed properly and tested by a trained in-
stallation or service professional. 
2.  Unit must be clean and grease-free prior to use. 
3.  Verify that the grease pan, heat duct and air filters are installed 
4.  Open door, locate switch to the right of the controller and turn power on. 
The motors should begin to turn and create airflow. 
5.  Unit will automatically begin to preheat, allow 20 minutes for unit to 
climb to operating temperature of 160º degrees F. 
6.  Load product into Crisp n’ Hold. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Product Divider 
On/Off Switch 
Food Bay 
 
 
 
 
 
CONTROLLER PROGRAMMING 
The controller has been factory pre-set at 175
°F (79°C), and has a low tem-
perature alarm pre-set for 140
°F (60°C). 
 
To View or Change the Temperature Setpoints 
Turn the power on. To view the temperature setpoint, press and hold the tem-
perature set button. To change the temperature setpoint, press and hold the 
temperature set button; press the up or down arrow button until the desired 
air temperature is displayed. The display will advance in 1
° increments. 
 
To View or Change Alarm Setpoints 
Turn the power on. To view the alarm setpoint, press and hold the alarm re-
set button; press the up or down arrow button until the desired alarm tem-
perature is displayed. The display will advance in 1
° increments. 
 
To View or Change the Temperature Scale 
The cabinet is programmable for a temperature scale in degrees Fahrenheit 
and Centigrade (Celsius). Turn power off. Hold down both arrow buttons and 
while holding both arrows, turn power back on. Display will show current 
scale (
°C or °F). If desired, push the up or down arrow to change the scale. 
 
6
CAUTION: 
HOT SURFACE 
 
Inner surfaces of the unit 
will be very hot during and 
after operation. 
 
Avoid touching the cabinet 
when loading or removing 
product. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Heat “ON” Indicator 
Display 
 
 
 
175 
 
 
 
Alarm 
Temperature 
Up and 
Reset 
Set Button 
Down 
Button 
Arrow 
Buttons