Phase Technology Motion Sensor FP Series User Manual

Page of 3
2. Remove motion sensor 
pod cover.
3. Remove motion sensor lens. 4. Place narrow lens into pod 
cover. Make sure lens is flush 
with outside of pod cover. 
Align the flat side of the lens w/ 
the flat side of the pod cover.
5. Place pod cover back on 
FP unit.
6. Complete.
Install Instructions For:
To adjust the sensor from wide angle to narrow angle:
 
Motion Sensor
1.435.647.9555 
|
 800.647.TUBE 
www.soundtube.com
FP Series
FP Series
FP Series
1. Unpack FP speaker pod 
and FP Dome. 
Orange White /
Orange
Blue White (unused)
Green (unused)
Brown White /
Brown
     
White/Green 
Signal 
wire
for 5 Volt ttl signal
Power supply and voltage sensor control 
not included.
 
1. Attach the +12 V from the power supply to the  
 
    Orange white and orange wire pair. 
2. Attach the ground from the power supply to the brown      
    white and brown wire pair. 
3. Attach the ground from the voltage sensor controller to 
    the brown and white wire pair also. 
4. Attach the signal wire to the white/green single wire. 
 
5 Volt ttl signal (White/Green Signal wire)
       • 0 Volts = motion detected
       • 5 Volts = no motion detected
       • The green and blue/white  
          wires are unused.
1k to 12 Volt pullup (Blue Signal wire)
       • 12 Volts = motion detected
       • 0 Volts = no motion detected
       • The green and blue/white  
          wires are unused.
Wiring Diagram for Motion Sensor
Power Source
Cat V Wire From Pod
Voltage Sensor Controller
Blue Signal wire for 
1k to 12 Volt pullup
Signal wire
Ground
Ground
Positive
(not included)
(not included)