Pepper Computer Modular Computers RS232 User Manual

Page of 320
SMART I/O User’s Manual
©1996 PEP Modular Computers GmbH
March 12, 1996
Page 5 - 41
5
Chapter 5  Analog Modules
5.2.8.4 SMADCSetCyclicCalib
Syntax
error_code SMADCSetCyclicCalib(u_int8 PortNr, u_int
secs);
Description
This function sets the time between two calibration cycles in seconds. If
secs=0, then cyclic calibration is disabled.
Input
u_int8 PortNr
Port number of module for calibration
(from 0 to 10)
u_int16 secs
Time in seconds between two calibration
cycles
Output
error_code
SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCSetCyclicCalib(0 , 120);