Pepper Computer Modular Computers RS232 User Manual

Page of 320
SMART I/O User’s Manual
©1996 PEP Modular Computers GmbH
October 01, 1996
Page 5 - 97
5
Chapter 5  Analog Modules
5.4.8.4 SMADC1GetV
Syntax
error_code SMADC1GetV(u_int8 PortNr, u_int8 Channel,
      int16 *pValue);
Description
This function fetches the conversion result of a selected channel. A gain and
offset correction is performed and the result stored as a signed integer value.
Input
u_int8 PortNr
SM-Port to be accessed
u_int8 Channel
Number of the ADC input channel to access
(0-3)
int16 *pValue
Pointer to the location where the conversion
result will be stored
Output
error_code
SUCCESS
E_SEEK
if module was not initialised
E-BMODE
if the module is unknown
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADC1GetV(0, 2, 0x07FF);
Value (16-bit HEX)
Unipolar
Bipolar
Positive Full-Scale
$0FFF
Positive Full-Scale
$07FF
+1LSB
$0001
+1LSB
$0001
0
$0000
0
$0000
  
-1LSB
$FFFF
Negative Full-Scale
$F800