Pelco TW3000P Series C1662M-A User Manual

Page of 12
6
C1662M-A (1/06)
APPLICATIONS
Figures 3 through 6 show how to use the transceivers in various applications. Always connect + to + 
and - to -. The TW3032P is used as an example in Figures 3 through 6.
Table A shows the distance in feet with Coaxitron or video only when using a particular type of Cat 
cable. Table B shows the maximum allowable wire gauge for single wire and stranded wire.
NOTE:  Cat5e cable is recommended for optimum video performance.
Figure 3.  Connecting Two Transceivers
Table A.  Cable Distance
Cable Type
Distance 
(with Coaxitron)
Distance 
(video only)
Cat3
300 ft
400 ft
Cat5
500 ft
650 ft
Cat5e
750 ft
750 ft
Cat6
750 ft
750 ft
Table B.  Wire Gauge
Wire Gauge (maximum allowable)
Single Wire (solid)
24 AWG (1.5 mm
2
)
Stranded Wire (flexible)
24 AWG (1.0 mm
2
)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
TW3032P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
TW3032P
MONITOR
UTP
+
-
+
-
FIXED CAMERA