CAMERA PROGRAMMING
Extended Coaxitron protocol receivers can be operated without any programming changes, other than changing the camera title, if
necessary. For other receiver control protocols, you must select the control type for the device connected to each video input.
If necessary, first program logical camera number.
PROGRAM LOGICAL NUMBERS
Default logical numbers start at 0001 and continue sequentially to 0032. To use a different numbering scheme, program new numbers on
the Logical Camera Number screen.
Figure 34.  Program Logical Camera Numbers
The numbers in the PHY columns are the physical input numbers; each represents an actual BNC input on the rear panel of the CM6800
and cannot be changed.
In the LOG field for each physical camera input, assign a valid logical number (0001-9998). A valid number is any number from 0001 to
9998 that has not already been assigned to a physical camera input.
NOTE:  If you change a logical number, you cannot control the camera until you select the new logical number from the keyboard.
PELCO SWITCHER
MODEL CM6800
MAIN MENU
1
CAMERA
2
LOGICAL CAMERA
3
MONITOR
4
ACCESS
5
TIME & DATE
6
PORT
7
PRIORITY
8
SEQUENCE
9
MACRO
10
ALARM CONTACTS
11
EVENT TIMER
12
SET AUXILIARY
13
SET PASSWORD
14
ABOUT CM6800
ENGLISH
RETURN
00654
LOGICAL CAMERA NUMBER MENU
PHY
LOG
PHY
LOG
01
0001 17
0402
02
0002 18
0403
03
0003 19
0404
04
0004 20
0405
05
0005 21
0500
06
0006 22
0501
07
0007 23
0502
08
0008 24
0503
09
0009 25
0504
10
0201 26
0505
11
0202 27
0601
12
0203 28
0602
13
0301 29
0603
14
0302 30
0604
15
0303 31
0605
16
0401 32
0032
RETURN