Pelco Computer Keyboard KBD4000 User Manual

Page of 43
Pelco Manual C1921M-G (1/04)
11
IMPORTANT: 
 The Genex
multiplexer lets you work in
any of four languages:
English (default), French,
German, or Spanish. If you
need to change the lan-
guage, do so before pro-
gramming because you
must reset the multiplexer to
factory defaults 
before
 you
can change the language.
See the MX4000 Genex
Series Simplex and Duplex
Multiplexers Installation/
Operation Manual for details.
NOTE:
  To program a multi-
plexer if a multiplexer server
is installed, you 
must
 enter
programming mode from the
multiplexer’s front panel.
After doing so, you can pro-
gram the multiplexer
through its front panel or
you can navigate and make
programming selections
through the keyboard.
PROGRAMMING
This section applies only to programming the multiplexer. The multiplexer can be
programmed from the keyboard or from the multiplexer’s front panel. To program the
multiplexer from the front panel, refer to the multiplexer manual. To program the
multiplexer server, refer to the server manual.
Programming lets you configure the multiplexer (from the KBD4000) for the way you want your
system to operate. The multiplexer automatically selects the most common operating param-
eters. However, some minimal programming may be required to make your system work.
Programming of system, camera, and VCR setup; camera sequencing; and alarm and
activity detection is done through on-screen menus displayed on the main monitor. You can
enable a password to prevent unauthorized access to the menus.
Programming of the picture-in-picture, and 4-, 9-, and 16-camera displays can be done
directly without going through menus. (Refer to the 
Multiple Camera Display Setup
 section.
CONTROLLING THE MULTIPLEXER WITH THE KEYBOARD
IMPORTANT INSTRUCTIONS
Before you can use the keyboard to control the multiplexer(s), do the following at the front
panel of the multiplexer(s)
.
VCR
LIVE
Duplex Color Multiplexer
00019
1.
Press the VIEW button for about three seconds. The basic System Setup menu
appears and the currently selected menu item blinks.
2.
Use the arrow buttons to highlight ADVANCED SETUP.
3.
Press the +/- button. The Advanced System Setup menu appears. Skip steps 4 and 5
if your system has only one multiplexer.
4.
Use the arrow buttons to move the cursor to UNIT ID.
5.
Press the +/- button to select the multiplexer’s UNIT ID.
6.
Use the arrow buttons to move the cursor to COMM TYPE.
In polled communication mode (switch 4 off), one multiplexer must be the
master and all others slaves.
In non-polled mode (switch 4 on), all multiplexers must be slaves (the
keyboard is master).
7.
Use the arrow buttons to go to EXIT. Press the +/- button to exit the menu. You can
now use the keyboard to program the multiplexer(s).
PASSWORD
You can program the multiplexer to request a password for access to programming menus.
Refer to the 
Advanced System Setup
 section for information on enabling the password.
The universal password is 3916 and cannot be changed. You must enter this password
whenever the system requests one. Enter it from the keyboard by pressing each number
followed by the CAM key (3, CAM, 9, CAM, 1, CAM, 6, CAM).
Figure 3.  Multiplexer Front Panel