22
Pelco Manual C1921M-G (1/04)
(If you play back the tape on the same equipment, any covert picture will still appear
blanked. Change the setting to NORMAL to see the picture.)
Video Termination
Set to 75 OHM when equipment is connected to the video IN connector only.
Set to LOOP HI-Z when equipment is also connected to the video OUT (looping)
connector. Equipment connected to the looping connector must be terminated at
75 ohms.
Alarm Input
Normally closed operation
= current flow
= alarm switch or relay closed
Normally open operation
= current flow
= alarm switch or relay open
Coaxitron Format 
EXTENDED – Use when your system has moveable cameras controlled by 32-
bit Coaxitron receivers, such as Esprit, Intercept, Spectra, and the LRD41C21/
LRD41C22 Series.
OFF – Use when your system has fixed cameras only.
STANDARD – Use when your system has moveable cameras controlled by 15-bit
Coaxitron receivers, such as the CX9000 Series, the PT7700, and the ED25/27/
28/29.
Activity Detection
A camera can be set to respond or not respond to activity. If enabled, select SET
DETECTION MASK to define what part of the camera’s viewing field will be monitored
for activity.
5.
To program another camera, press the number key for that camera, and then press
the CAM key. Repeat steps 2-4.
6.
When you finish all the changes you want to make, go to EXIT.
7.
Press the OPEN key to exit programming mode.
When HELP is highlighted, you can press the OPEN key to display a help screen that tells
you which keys to press to configure specific options.
NOTE:
  The Coaxitron
format default setting is
EXTENDED.