Parker Products COMPAX-M /-S (L) User Manual

Page of 242
Switch-on status
COMPAX-M / -S
10
5. Switch-on status
5.1 Configuration 
when 
supplied
When supplied, COMPAX is not configured. Parameter P149 is set to "0":
P149="0":
COMPAX is not configured and switches to OFF mode when switched
on (24V DC and operating voltage) (motor switched off). In addition to
this, when switched on, all parameters (apart from bus settings P194,
P195, P196 and P250) are set to their default values.
P149="1":
COMPAX is configured and once switched on (24V DC and operating
voltage) tries to engage the motor.
5.2 Commissioning
Meaning of LEDs on the front panel
COMPAX-M / -S
LED
Color
Meaning, when switched on
Ready
green
24V DC present and initialization complete
Error
red
COMPAX - Error (E1...E56) present or COMPAX is
initialized.
Mains module
LED
red
Error
LED
green
Ready
Possible errors
off
on
no errors
on
off
Heat sink temperature too high or
error in logic voltage (24V DC too low or unit is defective)
Emergency stop is activated and ready contact is
released.
on
on
Ballast switching unit overload or
undervoltage (<100V DC or <80V AC).
COMPAX 1000SL
Status
Red LED (H2)
Green LED (H1)
24V not available
off
off
24V are switched on, boot up
on
off
Unit OFF
off
blinking
Unit error; drive switched off
on
blinking
Unit error; drive powered
on
on
Unit RUNNING
off
on
Caution!
If there is no control voltage, no displays will appear to indicate
that operating voltage is present.
With Error E40, external enabling is missing with COMPAX 45XXS, COMPAX
85XXS and COMPAX 1000SL (Hardware input).
Note: