Parker Products COMPAX-M /-S (L) User Manual

Page of 242
Interfaces
63
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
7.9.11  HEDA interface (option A1/A4)
The HEDA interface is available for COMPAX XX00, COMPAX XX60 and
COMPAX XX70.
HEDA option A4: for COMPAX 1000SL
HEDA option A1: for all other COMPAX
IPM - COMPAX and COMPAX - COMPAX
housing
4 x 2 x 0.25mm   + shield
2
housing
D-pin 9-way
D-plug shell 9-way
1
5
6
9
1
5
6
9
RxC    2
RxC/   6
RxD    4
RxD/   8
TxC    3
TxC/   7
TxD    5
TxD/   9
2   RxC
6   RxC/
4   RxD
8   RxD/
3   TxC
7   TxC/
5   TxD
9   TxD/
1
1
X15
X14/PC
NC
NC
data from Slave
clock from Slave
data from Master
clock from Master
SSK14 must not be used on a COMPAX which is configured as a master
(P243=1).
Cables for COMPAX master and COMPAX slave coupling:
housing
2 x 2 x 0.25mm   +  shield
2
1
5
6
9
1
5
6
9
TxC    3
TxC/   7
TxD    5
TxD/   9
housing
D-pin 9-way
D-plug shell 9-way
Slave: X14
Master: X15
2   RxC
6   RxC/
4   RxD
8   RxD/
The last unit on the HEDA has a terminating connector (BUS2/01).
BUS 2/01
1
5
6
9
X15
RxC    2
RxC/   6
RxD    4
RxD/   8
TxC    3
TxC/   7
TxD    5
TxD/   9
1
NC
150
Ω
150
Ω
D-pin socket 9-way
D-plug shell 9-way
150
Ω
150
Ω
7.9.12 Bus connection
Special operating instructions are available for the bus systems.
Cable plan
SSK14/..:
Cable plan
SSK15/..
Terminating
connector
(BUS2/01).