Parker Products COMPAX-M /-S (L) User Manual
Operating Instructions
COMPAX-M / -S
Setting/resetting an output [OUTPUT]
98
8.4.5 Setting/resetting an output [OUTPUT]
OUTPUT output = 1/0
Output O1
Output O1
N005: OUTPUT O8=1 Sets output 8
N005: OUTPUT O8=0 Resets output 8
N005: OUTPUT O8=0 Resets output 8
8.4.6 Setting multiple digital outputs [OUTPUT O12=1010]
Multiple outputs can be set simultaneously.
OUTPUT O12=1010
OUTPUT O10=01--011 ("-"
OUTPUT O10=01--011 ("-"
O10="0"; O11="1"; O12, O13 are not changed; O14="0"; O15=O16="1".
(this is valid for max. 8 outputs)
(this is valid for max. 8 outputs)
♦
A maximum of 8 outputs can be processed per OUTPUT command.
♦
The comparator command "POSR .... OUTPUT ...." is still limited to setting one
output.
8.4.7 Switch off drive unit. [OUTPUT O0]
OUTPUT O0 = number
Number:
Number:
0/3:
drive subject to torque when brake is open.
1:
Drive 9 switched off when brake is closed.
2:
Drive switched off when brake is open.
Note: The command can only be set within a program with COMPAX XX00 and
COMPAX XX60
COMPAX XX60
! (see below!)
OUTPUT O0=1 Drive switched off when brake closed.
8.4.8 OUTPUT O0=... in program
The command OUTPUT O0=0,1,2 can only be programmed on the COMPAX
XX00 and COMPAX XX60
XX00 and COMPAX XX60
in the program.
No error monitoring is executed during switched off status except for emergency
stop (E55/E56).
stop (E55/E56).
16
O1...O6 only if masked via P225.
17
Instead of "-", "." is also an option
OUTPUT
Syntax:
Example:
OUTPUT
O12=1010
O12=1010
Syntax:
Note
OUTPUT O0
Syntax:
Example:
Limitation:
POSA
POSR
SPEED
ACCEL
OUTPUT
Password
SPEED
SYNC
Mark
reference
POSR
SPEED
POSR
OUTPUT
Cam
controller
WAIT
GOTO
GOSUB
RETURN
END
REPEAT
IF I..
Comparison
WAIT Start
GOTO /
GOSUB EXT
IF Error/ Stop
Arithmetic
Position
monitoring
Idle display
Speed
monitoring
Engage /
disengage
brake / final
stage
Variable
voltage