1. Network Management Specification
8000-A2-GB30-00
June 2003
23
4.1.5
“ifSpeed” Object (ifEntry 5) 
This object provides the interfaces’s current bandwidth in bits per second. The value of this 
object for each interface will be specified as follows:
4.1.6
“ifPhysAddress” Object (ifEntry 6) 
This object is used to specify the interface’s address at its protocol sub-layer. The interface’s 
media-specific MIB must define the bit and byte ordering and format of the value contained 
by this object. For the GranDSLAM 3.0 interfaces, this object should only contain the 
ethernet address (MAC Address) of the unit. All other interfaces are in blank.
4.1.7
“ifAdminStatus” Object (ifEntry 7) 
This object is used to specify the desired state (configuration) of the interface. When the 
GranDSLAM 3.0 initializes, all physical interfaces start with ifAdminStatus in the up(1) 
state. As a result of either explicit management action or per configuration ifAdminStatus 
is changed to down(2). The ifAdminStatus values which may be assigned to each interface 
after initialization are listed in the following table:
Table 1-10. ifSpeed
Interface
ifSpeed
AAL5
0
ATMUP
155000000
DSL
16000000
DSLATM
16000000
DSLChan
16000000
E1
2048000
ETH
100000000
IMA
[1544000..8*2048000]
SONET
155000000
SONETPath
155000000
T1