1. Network Management Specification
8000-A2-GB30-00
June 2003
93
10.1.5
pdnSyslogSeverityThreshold (RW):
The valid values are emerg (0), alert (1), critical (2), error (3), warning (4), notice (5), 
info (6),  debug (7). This value corresponds to a minimum severity level that a syslog 
messages can  be set.  All syslog message with an enum value greater than the threshold will 
not be sent.  The values are obtain from the RFC 3164, The BSD Syslog Protocol: 
                 emerg    (0) - Emergency: system is unusable
                 alert    (1) - Alert: action must be taken immediately
                 critical (2) - Critical: critical conditions
                 error    (3) - Error: error conditions 
                 warning  (4) - Warning: warning conditions
                 notice   (5) - Notice: normal but significant condition
                 info     (6) - Informational: informational messages
                 debug    (7) - Debug: debug-level messages
10.1.6
pdnSyslogRemoteDaemon (RW):
This value allows user to disable or enable syslog messages going to a remote daemon.
10.1.7
pdnEntitySyslogTable (NA):
This table supports retrieval of the syslog messages. It is indexed by the entPhysicalIndex 
and the pdnSyslogNumber. It allows the clasification of messages per entity (for example, 
per port card). The table objects are :
10.1.7.1
pdnEntitySyslogNumber (NA):
This is a sequentially increasing index of syslog messages starting at 1.  When the table 
reaches its maximum size  (as defined by pdnSyslogMaxTableSize) then the oldest message 
will be dropped without renumbering any messages that remain.  The index is reset to 1 on 
a device reset or when the table is cleared (using pdnSyslogClearTable).
10.1.7.2
pdnEntitySyslogMessage (RO):
The text of the syslog message.
10.1.8
pdnSyslogNumOfMsgInTable (RO):
This value let the users know how many syslog messages are currently in the syslog table. 
10.1.9
pdnSyslogMaxTableSize (RO):
The maximum number of syslog message the syslog table can hold.
10.1.10 pdnSyslogClearTable (RW):
Valid values are noOp(1) and clear (2). This object clears all the entries in the syslog 
message table.
10.1.11 pdnSyslogMsgToConsole (RW):
Valid values are disable (1), enable (2). This allows messages to be sent to the device’s 
console port. Note this is intended for debug use only! It is not recommended to be used to 
monitor syslog message  on a regular bases.  If one needs to constantly monitor  the syslog 
messages, then they should use the remote syslog   daemon, or other user interfaces.