Toro EC-XTRA Landscape Timer, 6-Zone (53794) Installation Guide

Page of 44
Installing the Cabinet
1.  For safe, reliable operation, select an installation site 
which will provide the following conditions:
  • Protection from irrigation spray, exposure to direct 
sun during the hottest hours, wind and snow.
  • Access to a grounded power source which is not 
controlled by a light switch or utilized by a high  
current load appliance, such as a refrigerator or air 
conditioner.
  • Access to the sprinkler control valve wiring and 
optional accessory wiring.
2.  Drive a wood screw (provided) into the wall at eye 
level (A). Leave the screw extended approximately 
1/4″ from the wall. 
  Note
: If you are installing the timer on drywall or 
masonry, install screw anchors to prevent screws 
from loosening. Use the dimension shown to predrill 
holes for screw anchors.
3.  Hang the cabinet on the screw using the keyhole  
slot (B) on the back panel. Make sure the cabinet 
slides down securely on the screw.
4.  Install the lower mounting screw(s) and tighten 
securely.
  Note: Conduit and adapters are not provided. Install 
conduit as required by local electrical codes.
5.  Install 1/2″ conduit (C) for power/equipment ground 
wires and 3/4″ conduit (D) for valve wires.
  Note: After installation, store the Quick Start Guide 
on the hook located on the inside of the door.
0
MANUAL
START
ON
NEXT
OFF
6
 
(15.24mm) 
B
A
D
C