Toshiba Oxygen Equipment LF620F User Manual

Page of 14
TIC-LF654L 
 15 
 
Table 5.  Specification Code for converters 
Model Specification 
Code 
Contents 
LF620 
type
LF622 
type 
1 2 3 4 5 6 7 8 9 10 11 12 
13 14 
F 6 2       
   Electromagnetic 
flowmeter 
converter 
    0      
   Combined 
(Integral) 
type 

– 
    2      
   Separate 
(Remote) 
type 
– 
 
   
 
   
 
 
 
 
 
 
 
  Purpose 
cFMus class I,  Division 2 approved 
 
 
 
 
   
 
   
 
 
 
 
 
 
 
   
 
     
 
 
 
 
 
 
  Shape 
Standard type with case 
 
 
 
   
 
   
   
 

  
   Converter 
mounting 
fitting 
None 
Panel, Accessory for wall mounting  (BNP material: SUS304) 
Accessory for pipe installation  (BNP material: SUS304) 
 
 
– 
– 
 
 

 
   
 
   
 
     
 
 
   Digital 
input/output 
Digital output points 2 (DO1+DO2) +Digital input point 1 (DI) 
 
 
 
 
   
 
   
 
 
 
 
1
2
3
 
 
  Current output and Communication function(Note1) 
    Current output + HART communication 
    PROFIBUS communication 
  Current output + Modbus (RS485) communication  
 
 
 
 
 
 
 
 
 
   
 
   
 
 
 
   


   Power 
supply(Note2) 
100Vac-240Vac 50/60Hz, 110Vdc 
24Vdc 
110Vdc 
 
 
 
 
 
 
 
 
   
 
   
 
 
 
 
 
 
  Instruction 
manual 
English 
 
 
 
 
 Code explanation: : Standard     : Option      –: Not available 
Note 1: When PROFIBUS communication is provided, current output(4-20mA) and HART communication cannot be used. 
When Modbus communication is provided, digital output points 1(DO1) and digital output points (DO2),  
digital input point 1(DI), HART communication cannot be used. 
     
Refer  to Table 6 for more details. 
Note2: Select 110Vdc for test report inspected under the condition of 110Vdc. 
 
 
Table6.  Communication functions and output selection table 
 
           
Selection of Function  
Availability of outputs 
Code 
(10
th
 digit) 
Selected 
Communication
4-20mAdc
DO1 DO2  DI 
1 HART 

 

 
2 PROFIBUS 
 

 
3 Modbus 
 
 
(Note) 
 
 
Code explanation: :Available    X:Not Available 
 
Note: When digital output 1 function and Modbus communication function are used at one time, TG (signal ground) of the  
Modbus communication function cannot be connected (2 line connection). 
 
 
                
  
ISO9001 and ISO14001 are certified.
 
 
 
Misuse of this product can result in damages to property or human injury. 
Read related manuals carefully before using this product.
 
Specifications are subject to change without notice.
Printed in Japan 2012-7 (TDOC)
© TOSHIBA Corporation 2012
All Rights Reserved.
http://www.toshiba.com/ind/