13.7.2. Utility setting items
• C-IN:
Sets the functions to be assigned to the control input terminals, or control buttons when ZM-
9001 or ZM-9002 is used. Assigning a function to these terminals or control buttons
overwrites the previously set functions on them if there are.
• C-OUT:
Sets the functions to be assigned to the control output terminals. Assigning a function to
these terminals overwrites the previously set functions on them if there are.
• POWER OFF: Sets whether or not to save data of the volume level set in normal use state when the AC
power supply is cut off. 
• VOX TIME:
Sets the release time (seconds) for the signals interrupted by the VOX function.
• RS232C:
Sets the RS-232C communication speed. 
• MODULE:
Displays or sets the module classification.
• PRIORITY:
Sets priority order when multiple inputs with the same priority are broadcast.
• REMOTE:
Sets the input and output channels for which the volume is remotely adjusted. 
• ANC:
If  there are 2 or more ANC inputs, sets whether or not ANC inputs to be monitored are
switched.
• EVENT:
Sets the Event that is activated when the unit's power is turned on. (Only in the normal
matrix operation)
• CHANNEL:
Sets the input channel that is activated when the unit's power is turned on. (Only in the 1-
channel or 2-channel output operation)
• SUB-MODE:
Sets the operation method.
• VERSION:
Displays the firmware version.
• MEMORY:
Initializes memory.
(C1) Function selection
U T I L I T Y
C - I N
Unless otherwise specified, use the Parameter setting knob for each parameter selection.
C-IN (control input, default), C-OUT (control output), POWEROFF, VOX TIME (VOX
release time), RS232C, MODULE, PRIORITY, REMOTE (remote volume), ANC (ANC
monitor), EVENT (Event activation at power-on), CHANNEL (input channel activation at
power-on), SUB-MODE (operation method), VERSION, MEMORY (memory initialization)
Setting Range
C-IN01 – 04 (C-IN01 – 12 when C-001T is used), ZM-IN01 – 12* (default: C-IN01)
Selectable only when the Remote controller type (
Setting Range
(C2) Control input number selection
C - I N 0 1
N O N E
The screen indications ZM-IN01 – 06 or 01 – 04 correspond to the control buttons of the ZM-9001 or ZM-9002
connected to the 9000 Series amplifier's remote volume control terminal 1 (REMT VOL 1). The indications of
ZM-IN with subsequent numbers correspond to ZM-9001's or ZM-9002's control buttons connected to the
remote volume control terminal 2 (REMT VOL 2).
In the normal matrix operation, when the Down shift key is pressed with the control input function set to NONE
and the cursor at the control input number, the Event number assigned to that control input number can be
confirmed. 
If no Event is assigned to that control input number, the NONE indication is displayed.
[When the function is set to C-IN:]