Test-Um NT955 Series
5.4. Step by Step Instructions for Performing Manual Tests
1.  From the Start Menu, select Manual Tests.  Choose
 Data, Phone 
or
 2-wire cable type.
Warning! Manual Test Results will NOT be saved.
 
2.  Using the appropriate cable assembly and jacks, connect 
the Validator-NT main unit to the cable identified in the Test 
Schedule with the Remote Unit connected to the opposite end.
Cable Test
1.  Select Cable Test to initiate a test sequence. The wiremap, 
length, SNR, and Skew results will display. (Figure 5.5)
2.  The up and down arrow keys adjust the length constant by .1 
pF increments if the cable requires a different setting than that 
displayed at the top of the screen.
3.  On the DATA test screen, the Length (F1) soft key can be used 
to run the length portion of the test sequence only, skipping the 
Skew and SNR tests.
Wiremap - DATA
Untitled1.job
Results                       Length              Skew      SNR
34ft
34ft
33ft
34ft
1                         1
2                         2
3                         3
6                         6
4                         4
5                         5
7                         7
8                         8
S                         S
Remote ID: 1                    Length Constant: 15 PF/ft.
A                                   1.6         30.0
B                                   0.0         30.0          
C                                   1.9         30.0
D                                   0.0         30.0
Up and Down controls Length Constant
LENGTH
Test-Um Inc.
validator
100%
2005 Aug 25
  10:53:01
-X
Figure 5.5 Manually Testing Cables
Validator
TM
 Running Manual Tests